summaryrefslogtreecommitdiff
path: root/tools/perf/scripts/python
diff options
context:
space:
mode:
authorAhmad Fatoum <a.fatoum@pengutronix.de>2021-08-09 18:20:31 +0200
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2021-11-26 11:58:41 +0100
commitcf756a7bfa3d3f0b3ac2b6238eb5dbc1bea99605 (patch)
tree111af241983f4d969021fa3dd264c5c985d7c177 /tools/perf/scripts/python
parentf742386cb60fde620aabd39a7a4b9941aa4778e1 (diff)
watchdog: f71808e_wdt: fix inaccurate report in WDIOC_GETTIMEOUT
[ Upstream commit 164483c735190775f29d0dcbac0363adc51a068d ] The fintek watchdog timer can configure timeouts of second granularity only up to 255 seconds. Beyond that, the timeout needs to be configured with minute granularity. WDIOC_GETTIMEOUT should report the actual timeout configured, not just echo back the timeout configured by the user. Do so. Fixes: 96cb4eb019ce ("watchdog: f71808e_wdt: new watchdog driver for Fintek F71808E and F71882FG") Suggested-by: Guenter Roeck <linux@roeck-us.net> Reviewed-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Ahmad Fatoum <a.fatoum@pengutronix.de> Link: https://lore.kernel.org/r/5e17960fe8cc0e3cb2ba53de4730b75d9a0f33d5.1628525954.git-series.a.fatoum@pengutronix.de Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org> Signed-off-by: Sasha Levin <sashal@kernel.org>
Diffstat (limited to 'tools/perf/scripts/python')