authorGeert Uytterhoeven <geert+renesas@glider.be>2019-03-20 11:32:14 +0100
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2019-05-16 19:45:00 +0200
commit6c24038d84a7a133ed318c036c483e8fd6b643f6 (patch)
tree062aedd8571faa7be7f7b3b18256252621b1c706 /tools/perf/scripts/python/call-graph-from-postgresql.py
parente9358b9a5db175b02a67c01c2141c721bdfc63a8 (diff)
rtc: sh: Fix invalid alarm warning for non-enabled alarm
[ Upstream commit 15d82d22498784966df8e4696174a16b02cc1052 ] When no alarm has been programmed on RSK-RZA1, an error message is printed during boot: rtc rtc0: invalid alarm value: 2019-03-14T255:255:255 sh_rtc_read_alarm_value() returns 0xff when querying a hardware alarm field that is not enabled. __rtc_read_alarm() validates the received alarm values, and fills in missing fields when needed. While 0xff is handled fine for the year, month, and day fields, and corrected as considered being out-of-range, this is not the case for the hour, minute, and second fields, where -1 is expected for missing fields. Fix this by returning -1 instead, as this value is handled fine for all fields. Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com> Signed-off-by: Sasha Levin <sashal@kernel.org>