summaryrefslogtreecommitdiff
path: root/net
diff options
context:
space:
mode:
authorSubash Abhinov Kasiviswanathan <subashab@codeaurora.org>2016-02-05 13:43:15 -0700
committerDavid Keitel <dkeitel@codeaurora.org>2016-03-22 11:05:58 -0700
commit5e5cb4ce4eef5c55359296d53e7125b63adfae74 (patch)
tree8a5d3c3a527093bd38e98a3590e0bb550bfca851 /net
parent0dc9f20694811467244908f1b80f042b934a69d2 (diff)
net: rmnet_data: Remove the NETIF_F_IPV6_UDP_CSUM device feature
Commit 32dce968dd987ad ("ipv6: Allow for partial checksums on non-ufo packets) adds support for checksum offload in hardware for single UDP packets. As a result, the custom NETIF_F_IPV6_UDP_CSUM feature is no longer needed. Signed-off-by: Subash Abhinov Kasiviswanathan <subashab@codeaurora.org>
Diffstat (limited to 'net')
-rw-r--r--net/rmnet_data/rmnet_data_vnd.c3
1 files changed, 1 insertions, 2 deletions
diff --git a/net/rmnet_data/rmnet_data_vnd.c b/net/rmnet_data/rmnet_data_vnd.c
index 70f1701f1296..60e48e468b6c 100644
--- a/net/rmnet_data/rmnet_data_vnd.c
+++ b/net/rmnet_data/rmnet_data_vnd.c
@@ -593,8 +593,7 @@ int rmnet_vnd_create_dev(int id, struct net_device **new_device,
/* Configuring DL checksum offload on rmnet_data interfaces */
dev->hw_features = NETIF_F_RXCSUM;
/* Configuring UL checksum offload on rmnet_data interfaces */
- dev->hw_features |= NETIF_F_IP_CSUM | NETIF_F_IPV6_CSUM |
- NETIF_F_IPV6_UDP_CSUM;
+ dev->hw_features |= NETIF_F_IP_CSUM | NETIF_F_IPV6_CSUM;
/* Configuring GRO on rmnet_data interfaces */
dev->hw_features |= NETIF_F_GRO;
/* Configuring Scatter-Gather on rmnet_data interfaces */