Linux 3.14-rc5 * tag 'v3.14-rc5': (1117 commits) Linux 3.14-rc5 drm/vmwgfx: avoid null pointer dereference at failure paths drm/vmwgfx: Make sure backing mobs are cleared when allocated. Update driver date. drm/vmwgfx: Remove some unused surface formats MAINTAINERS: add maintainer entry for Armada DRM driver arm64: Fix !CONFIG_SMP kernel build arm64: mm: Add double logical invert to pte accessors dm cache: fix truncation bug when mapping I/O to >2TB fast device perf tools: Fix strict alias issue for find_first_bit powerpc/powernv: Fix indirect XSCOM unmangling powerpc/powernv: Fix opal_xscom_{read,write} prototype powerpc/powernv: Refactor PHB diag-data dump powerpc/powernv: Dump PHB diag-data immediately powerpc: Increase stack redzone for 64-bit userspace to 512 bytes powerpc/ftrace: bugfix for test_24bit_addr powerpc/crashdump : Fix page frame number check in copy_oldmem_page powerpc/le: Ensure that the 'stop-self' RTAS token is handled correctly kvm, vmx: Really fix lazy FPU on nested guest perf tools: fix BFD detection on opensuse drm/radeon: enable speaker allocation setup on dce3.2 ...
Diffstat (limited to 'arch/powerpc/sysdev/mpic.c')
-rw-r--r--arch/powerpc/sysdev/mpic.c38
1 files changed, 19 insertions, 19 deletions
diff --git a/arch/powerpc/sysdev/mpic.c b/arch/powerpc/sysdev/mpic.c
index 0e166ed4cd16..8209744b2829 100644
--- a/arch/powerpc/sysdev/mpic.c
+++ b/arch/powerpc/sysdev/mpic.c
@@ -886,25 +886,25 @@ int mpic_set_irq_type(struct irq_data *d, unsigned int flow_type)
/* Default: read HW settings */
if (flow_type == IRQ_TYPE_DEFAULT) {
- switch(vold & (MPIC_INFO(VECPRI_POLARITY_MASK) |
- MPIC_INFO(VECPRI_SENSE_MASK))) {
- case MPIC_INFO(VECPRI_SENSE_EDGE) |
- MPIC_INFO(VECPRI_POLARITY_POSITIVE):
- flow_type = IRQ_TYPE_EDGE_RISING;
- break;
- case MPIC_INFO(VECPRI_SENSE_EDGE) |
- MPIC_INFO(VECPRI_POLARITY_NEGATIVE):
- flow_type = IRQ_TYPE_EDGE_FALLING;
- break;
- case MPIC_INFO(VECPRI_SENSE_LEVEL) |
- MPIC_INFO(VECPRI_POLARITY_POSITIVE):
- flow_type = IRQ_TYPE_LEVEL_HIGH;
- break;
- case MPIC_INFO(VECPRI_SENSE_LEVEL) |
- MPIC_INFO(VECPRI_POLARITY_NEGATIVE):
- flow_type = IRQ_TYPE_LEVEL_LOW;
- break;
- }
+ int vold_ps;
+
+ vold_ps = vold & (MPIC_INFO(VECPRI_POLARITY_MASK) |
+ MPIC_INFO(VECPRI_SENSE_MASK));
+
+ if (vold_ps == (MPIC_INFO(VECPRI_SENSE_EDGE) |
+ MPIC_INFO(VECPRI_POLARITY_POSITIVE)))
+ flow_type = IRQ_TYPE_EDGE_RISING;
+ else if (vold_ps == (MPIC_INFO(VECPRI_SENSE_EDGE) |
+ MPIC_INFO(VECPRI_POLARITY_NEGATIVE)))
+ flow_type = IRQ_TYPE_EDGE_FALLING;
+ else if (vold_ps == (MPIC_INFO(VECPRI_SENSE_LEVEL) |
+ MPIC_INFO(VECPRI_POLARITY_POSITIVE)))
+ flow_type = IRQ_TYPE_LEVEL_HIGH;
+ else if (vold_ps == (MPIC_INFO(VECPRI_SENSE_LEVEL) |
+ MPIC_INFO(VECPRI_POLARITY_NEGATIVE)))
+ flow_type = IRQ_TYPE_LEVEL_LOW;
+ else
+ WARN_ONCE(1, "mpic: unknown IRQ type %d\n", vold);
}
/* Apply to irq desc */