msm8996-common: thermal-engine: Update thresholds for battery_monitor
* These temperatures are too low for us because this sensor basically fluctuates way too much. This causes a charging - not charging behaviour while charging the device normally. * The problem is probably not there in ZUI because they use the batt_therm sensor with the same configuration, but that probably behaves differently. * Partial revert of d18cab6881d234d29c8f2b51bcfd8340803aca9a Change-Id: I9b397568beb110455d65d6ce826dca59679f93b2 Signed-off-by: Davide Garberi <dade.garberi@gmail.com>
Diffstat (limited to 'configs')
-rw-r--r--configs/thermal-engine.conf6
1 files changed, 3 insertions, 3 deletions
diff --git a/configs/thermal-engine.conf b/configs/thermal-engine.conf
index 6a65025..ea3dac6 100644
--- a/configs/thermal-engine.conf
+++ b/configs/thermal-engine.conf
@@ -39,7 +39,7 @@ set_point_clr 65000
algo_type monitor
sensor tsens_tz_sensor17
sampling 1000
-thresholds 42000 43000 44000
-thresholds_clr 40000 42000 43000
+thresholds 43000 49000
+thresholds_clr 41000 47000
actions battery battery battery
-action_info 0 1 2
+action_info 0 1