parent | 9fd964c96783299ac8a30a6260a55f299c8e1dda (diff) |
msm8996-common: thermal-engine: use bms sensor for charging throttling
17th sensor get's way above 70C after 7-10 minutes of
CPU stress test and above 50C in normal usage. This kills charging
entirely. We do not want that because actually it does not
indicate that we are overheating. What we really need to check is
the battery temperature.
This change ensures that we have at least 400-500mA charging
even under heavy usage.
bms and battery sensors show the same temperature.
Change-Id: I3ac2152e06afcd0a27d228de89d635d32b3110bc
Signed-off-by: Yaroslav Furman <yaro330@gmail.com>
Signed-off-by: Davide Garberi <dade.garberi@gmail.com>
-rw-r--r-- | configs/thermal-engine.conf | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/configs/thermal-engine.conf b/configs/thermal-engine.conf index ea3dac6..4682dd5 100644 --- a/configs/thermal-engine.conf +++ b/configs/thermal-engine.conf @@ -37,7 +37,7 @@ set_point_clr 65000 [battery_monitor] algo_type monitor -sensor tsens_tz_sensor17 +sensor bms sampling 1000 thresholds 43000 49000 thresholds_clr 41000 47000 |